Weigh parcels with a scale

If you connect a shipping scale to a computer running Scanpacker Printer Connect, Scanpacker fills in the parcel weight on the ship page for you. When you put a parcel on the scale and the reading settles, the weight appears in the parcel’s Weight field, ready for you to buy a label.

Scanpacker works with two kinds of scale. USB scales that present themselves to the computer as a scale appear in Printer Connect on their own. Scales with a serial (RS-232) connection, usually through a USB serial adapter, need to be added by hand, and you choose the protocol and serial settings they use.

You need Printer Connect 1.1.1 or later. Printer Connect updates itself, so most computers already have it.

Connect a USB scale

  1. Plug the scale into the computer that runs Printer Connect, and switch it on.
  2. In Printer Connect, click Scales in the sidebar.
  3. If the scale isn’t in the list, click Find scales.

When Printer Connect can read the scale, its status is Connected, and the Weight column changes as you put something on the scale. A dot next to the weight turns green when the reading is stable, and yellow while the scale is still moving.

Connect a serial scale

A serial scale sends its weight as text, in a format that depends on the manufacturer. Printer Connect needs to know which format, called the protocol, and the serial settings the scale uses, before it can read the weight.

  1. Connect the scale to the computer, usually with a USB serial adapter, and switch it on.
  2. In Printer Connect, click Scales in the sidebar, then click Add serial scale….
  3. Choose the Serial port the scale is connected to. USB serial adapters are listed first.
  4. Choose the scale’s Protocol. Scanpacker supports these:
    • A&D (ST/US/OL format), used by A&D scales.
    • Ohaus (Ranger, Valor), used by Ohaus Ranger and Valor scales.
    • SMA (Fairbanks and others), a standard format used by Fairbanks and several other manufacturers.

    If your scale uses none of these, choose Not listed. See If your scale isn’t listed.

  5. Check the serial settings under Advanced. See Serial settings.
  6. Click Add scale.

Printer Connect opens the port straight away and shows the scale in the list. Put something on the scale and check that the weight appears.

Serial settings

The serial settings must match the scale exactly, or Printer Connect receives garbled text and can’t read a weight. They are:

  • Baud rate, the speed of the connection, such as 9600.
  • Data bits, usually 8, sometimes 7.
  • Parity, usually None, sometimes Even or Odd.
  • Stop bits, usually 1.

When the protocol’s manual gives the settings, as Ohaus’s does, Scanpacker fills them in when you choose the protocol. Otherwise it fills in 9600 baud, 8 data bits, no parity, and 1 stop bit, which is the most common setting but not the only one. To find your scale’s settings, look in the communication or RS-232 section of its setup menu, or in its manual. Many scales let you change these settings, so the values in the menu are the ones that count.

If you change a setting on the scale itself, some scales only use the new value after you switch them off and on again.

To go back to the settings Scanpacker suggests for the chosen protocol, click Reset to defaults.

To change the protocol or settings of a serial scale you’ve already added, click Add serial scale… and add it again on the same serial port. Printer Connect replaces its settings with the new ones.

Choose the scale for the ship page

After a scale is connected, it appears in Scanpacker under Settings > Scales, with the computer it’s connected to and its latest reading. You then choose which scale fills in the weight on the ship page.

  • If your shop uses stations: each station chooses its scale. Go to Settings > Stations, click Edit next to the station, choose the Scale, and click Save Changes. Everyone who packs at that station uses its scale.
  • If your shop doesn’t use stations: each staff member chooses their own. Go to Settings > Scales, choose a scale under Your scale for shipping, and click Save.

Weigh a parcel

Open the ship page for the order, then put the packed parcel on the scale. When the reading has been stable for a moment, Scanpacker puts the weight into the Weight field. If you’d already fetched rates, Scanpacker clears them, because they depend on the weight.

Scanpacker only uses a weight that settles after the scale moves while the ship page is open, and it uses it once. This means:

  • A parcel left on the scale from the previous order doesn’t fill in the next order’s weight. Lift it off and put it back, or put the new parcel on.
  • A weight you type in by hand stays, unless you then put something new on the scale.
  • The weight is filled in using the unit the scale reports, such as kilograms or pounds.

If your scale isn’t listed

If your scale uses a protocol Scanpacker doesn’t support yet, you can record what it sends and send the recording to us, so that we can add support for it.

  1. Add the scale as described in Connect a serial scale, with Protocol set to Not listed and the serial settings from the scale’s manual.
  2. In the list of scales, click Capture recording… next to the scale.
  3. Enter the scale’s make and model, and any notes that might help.
  4. Make sure there’s nothing on the scale, then click Start recording. Printer Connect shows each of the next steps on the screen as the recording runs.
  5. Put something on the scale, and press the scale’s Print button if it has one.
  6. Leave the item on the scale until the recording ends. For the last 10 seconds, Printer Connect asks the scale for its weight in each of the formats it knows, because some scales only send a weight when they’re asked.

After 30 seconds, Printer Connect sends the recording to us. To stop without sending anything, click Cancel before the countdown ends.

If the recording page says the scale sent nothing, the serial settings are usually wrong. Check them against the scale’s menu or manual, add the scale again, and make a new recording.

Troubleshooting

The scale doesn’t appear in Printer Connect. For a USB scale, check that it’s switched on and click Find scales. Some USB scales don’t present themselves as a scale, and those can’t be used. For a serial scale, check the cable and, on Windows, that the USB serial adapter’s driver is installed. If no serial ports are found, the adapter isn’t recognised by the computer.

The scale says Not connected. Another program on the computer may be using the serial port, such as the scale manufacturer’s own software. On Windows, only one program can use a serial port at a time. Close the other program, then add the scale again on the same serial port.

The scale is connected, but no weight appears. The protocol or the serial settings don’t match the scale. Check them in the scale’s setup menu or manual. If the settings are right and the scale still shows no weight, its protocol may not be supported yet; see If your scale isn’t listed.

The weight doesn’t fill in on the ship page. Check that you’ve chosen the scale in Settings > Scales or on your station, and that the computer it’s connected to has Printer Connect running. Then lift the parcel off the scale and put it back.

  • Printing — install Printer Connect, which also connects your scales
  • Stations — choose the printers and scale for each packing bench
  • Shipping label purchase — set the parcel size and weight, and buy labels